10KV |
35KV |
35KV |
110KV |
6KV |
10KV |
10KV |
220-380V |
Keystone: |
The zinc oxide arrester is the most advanced over-voltage protector in the world.Due to make the resistor disc of core component mainly adopt zine oxide arrester.Compared with the conventional silicon carbide arrrester,this presciption of the product improves greatly the volt-Amperecharacterisics of the resistor disc and increased through-current capability at over-voltage so as to bring a radical changes for the characteristics of the arresters. Under the circumstance of normal operating voltage ,the current through the arrester is just on mincroampere degree.When suffered from the current through the arrester increase to several thousand amperse,while the arrester will be under the circulating state and release over-voltage energry so as to protecting the power thansmission equipments against the damage caused by the over-voltage. |
Condition of Use: |
|
Applicationg & Characteristics: |
The zinc oxide arrester applies to protect the electrical equipment in AC power system against the damage resulted from atmospheris over-voltage and operational over-voltage. |
Defination of model : |
Technology Parameterr : |
Type |
Lightning arrester rated voltage(KV) |
System nominal voltage (KV) |
Cont- inuous operation voltage (KV) |
DC 1mA Voltage(KV) |
Lightning impulse residual voltage (KV) |
Steep current impulse residual voltage (KV) |
2ms square wave impulse current withstand (A) |
Service scope |
Y1.5W-0.28/1.3 |
0.28 |
0.22 |
0.24 |
0.6 |
1.3 |
- |
75 |
Low- voltage |
Y1.5W-0.5.2.6 |
0.5 |
0.38 |
0.42 |
1.2 |
2.6 |
- |
75 | |
Y5WS-3.8/1.7 |
3.8 |
3 |
2.0 |
7.51 |
17.0 |
19.6 |
100 |
Power of distribution |
Y5WS-7.6/30 |
7.6 |
6 |
4.0 |
15 |
30 |
34.5 |
100 | |
Y5WS-10/30 |
10 |
6 |
8.0 |
15 |
30 |
34.5 |
100 | |
Y5WS-12.4/50 |
12.7 |
10 |
6.6 |
25 |
50 |
57.5 |
100 | |
Y5WS-17/50 |
17 |
10 |
0.24 |
25 |
50 |
57.5 |
100 | |
Y5WZ-3.8/13.5 |
3.8 |
3 |
0.42 |
7.2 |
13.5 |
14.5 |
200 |
Transformer substation |
Y5WZ-7.6/27 |
7.6 |
6 |
2.0 |
14.4 |
27 |
31.0 |
200 | |
Y5WZ-10/27 |
10 |
6 |
4.0 |
14.4 |
27 |
31.0 |
200 | |
Y5WZ-12.7/45 |
12.7 |
10 |
8.0 |
24 |
45 |
51.8 |
200 | |
Y5WZ-17/45 |
17 |
10 |
6.6 |
24 |
45 |
51.8 |
200 | |
Y5WZ-42/134 |
42 |
35 |
13.6 |
73 |
134 |
154 |
400 | |
Y5WZ-51/134 |
51 |
35 |
40.8 |
73 |
134 |
154 |
400 | |
Y5WZ-100/260 |
100 |
110 |
78 |
145 |
260 |
291 |
400,600 | |
Y10WE-100/260 |
100 |
110 |
78 |
145 |
260 |
291 |
600,800 | |
Y2.5WD-3.8/9.5 |
3.8 |
3 |
2.0 |
5.7 |
9.5 |
10.7 |
400 |
Circumvolve Electrical machine |
Y2.5WD-7.6/19 |
7.6 |
6 |
4.0 |
11.2 |
19 |
21.9 |
400 | |
Y2.5WD-12.7/31 |
12.7 |
10 |
6.6 |
18.6 |
31 |
35.7 |
400 | |
Y5WR-3.8/13.5 |
3.8 |
3 |
2.0 |
7.2 |
13.5 |
14.8 |
400 |
Capacitor |
Y5WR-7.6/27 |
7.6 |
6 |
4.0 |
14.4 |
27 |
30.8 |
400 | |
Y5WR-10/27 |
10 |
6 |
8.0 |
14.4 |
27 |
31.0 |
400 | |
Y5WR-12.7/45 |
12.7 |
10 |
6.6 |
24 |
45 |
51 |
400 | |
Y5WR-17/45 |
17 |
10 |
13.6 |
24 |
45 |
51 |
400 | |
Y5WR-51/34 |
51 |
35 |
40.5 |
73 |
134 |
154 |
400 | |
Y1.5W-2.4/6 |
2.4 |
3.2* |
1.9 |
3.4 |
6 |
- |
5 |
Electrical machine neuter machine |
Y1.5W-4.8/12 |
4.8 |
6.3* |
3.8 |
6.8 |
12 |
- |
10 | |
Y1.5W-8/19 |
8 |
10.5 |
6.4 |
11.4 |
19 |
- |
15.9 | |
Y1.5W-60/144 |
60 |
110 |
48 |
85 |
144 |
- |
135 |
Transformer neuter point |
Y1.5W-72/86 |
72 |
110 |
58 |
103 |
186 |
- |
174 |
Type |
System nonminal voltage (KV) |
Lighting arrester rated voltage (KV) |
Power frequency discharge voltage (KV) |
1.2/50us impulse discharge voltage (KV) |
Front-of-wave impulse Discharge voltage |
Residual voltage on nominal current |
Impulse current with stand | |
2000us square wave (A) |
4/10us high current inpulse | |||||||
Y5CS-3.8/15 |
3 |
3.8 |
9 |
21 |
26.3 |
15 |
75 |
40 |
Y5CS-7.6/27 |
6 |
7.6 |
16 |
35 |
43.8 |
27 | ||
Y5CS-12.7/45 |
10 |
12.7 |
26 |
50 |
62.5 |
45 | ||
Y5CZ-3.8/12 |
3 |
3.8 |
9 |
20 |
25 |
12 |
75 |
65 |
Y5CZ-7.6/24 |
6 |
7.6 |
16 |
30 |
37.5 |
24 | ||
Y5CZ-12.7/41 |
10 |
12.7 |
26 |
45 |
56.5 |
41 |